| Paraiméadar | Luach |
|---|---|
| T2 | |
| Nóta | Usable in all low-voltage systems between L-N or L-PEN.Only usable in IT Systems between L-PE, if the exposed-conductive-parts (bodies) of the equipment of the low-voltage installation is connected to the earthing arrangement of the transformer substation. (interconnected earthing arrangement of the HV-transformer substation with the bodies of the LV-installation. RE= RAaccordance to IEC 60364-4-442 / VDE 0100-442 Fig. 44D / Example a) |
| Cineál | DIN rail module, two-section, divisible |
| Doimhneacht | 74.5 mm (incl. DIN rail 7.5 mm) |
| Leithead | 37.3 mm |
| Airde | ≤ 2000 m (amsl) |
| Cineál EN | T2 |
| Cineál táirge | Surge arrester |
| Snáithe scriú | M5 |
| Cineál gléasta | DIN rail: 35 mm |
| Grúpa ábhair | I |
| Teaghlach táirgí | SEC Family |
| Ainm an naisc | Remote fault indicator contact |
| Athbhreithniú airteagail | 03 |
| Páirc chothrománach | 2 Div. |
| Ábhar tithíochta | PA 6.6-FR 20 % GF |
| Céim truaillithe | 2 |
| Am freagartha tA | ≤ 25 ns |
| Fad stialladh | 16 mm |
| Modh ceangail | Screw connection |
| Sruth oibriúcháin | 5 mA AC ... 1 A AC |
| Voltas oibriúcháin | 5 V AC ... 250 V AC |
| Turraing (oibríocht) | 30g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z) |
| Chasmhóiminte teannaithe | 4.5 Nm |
| Mód cosanta | L-PEN |
| Voltas ainmniúil UN | 400/690 V AC (TN-C) |
| Feidhm lasctha | Changeover contact |
| Iompar TOV ag UT | 581 V AC (5 s / withstand mode) |
| Líníocht thoisí | |
| Treo na gníomhaíochta | 3L-N/PE |
| Ábhar inslithe | PA6.6-FR 20% GF |
| Líon na bpost | 3 |
| Dath (Eilimint bhunúsach) | gray (RAL 7042) |
| Céim chosanta | IP20 |
| Minicíocht ainmniúil fN | 50 Hz (60 Hz) |
| Catagóir róvoltais | III |
| Luach CTI an ábhair | 600 |
| Ualach reatha rátáilte IL | 40 A (Biconnect M4 fork-type cable lug 6 mm²) |
| Ures voltais iarmharaigh | ≤ 1.9 kV (at In) |
| Creathadh (oibriú) | 5g (10 ... 500 Hz / 2.5 h / X, Y, Z) |
| Dath (Nascóir fireann) | light gray (RAL 7035) |
| Córas soláthair cumhachta IEC | TN-C |
| Aicmiú tástála IEC | II |
| Caighdeáin/sonraíochtaí | IEC 61643-11 |
| Trasghearradh seoltóra AWG | 12 ... 4 |
| Leibhéal cosanta voltais suas | ≤ 1.9 kV |
| Tomhaltas cumhachta fuireachais ríomhaire | ≤ 540 mVA |
| Trasghearradh seoltóra righin | 2.5 mm² ... 25 mm² |
| Uasmhéid voltais leanúnach UC | 440 V AC |
| Teachtaireacht locht cosanta borrtha | Optical, remote indicator contact |
| Teocht chomhthimpeallach (oibriú) | -40 °C ... 80 °C |
| Trasghearradh seoltóra solúbtha | 2.5 mm² ... 16 mm² |
| Taise incheadaithe (oibríocht) | 5 % ... 95 % |
| Rátáil reatha gearrchiorcaid ISCCR | 25 kA (for a backup fuse of up to 315 A gG) |
| Uasmhéid fiús cúltaca le sreangú brainse | 315 A (gG) |
| Rátáil inadhainteachta de réir UL 94 | V-0 |
| Sruth urscaoilte ainmniúil In(8/20) µs | 20 kA |
| Teocht chomhthimpeallach (stóráil/iompar) | -40 °C ... 80 °C |
| Uasmhéid reatha urscaoilte Imax(8/20) µs | 40 kA |
| Uasmhéid fiús cúltaca le sreangú tríd an gcineál V | 40 A (gG / Biconnect M4 fork-type cable lug, 6 mm²) |
Sonraíochtaí teicniúla agus sonraí feidhmíochta