| Paraiméadar | Luach |
|---|---|
| Mír | Specifications |
| Meáchan | Net weight: 190 g approx.Gross weight: 320 g approx. |
| Táirge | Safety Control Unit |
| Ábhar | Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate |
| PFHD/ MTTFD | 9.73 x 10−10/ 100 years or more |
| Uimhir Chuid | SF-C21 |
| Fad cábla | 100 m328.084 ftor less |
| Ainm an táirge | Safety Control Unit SF-C21 |
| Uimhir Táirge | SF-C21 |
| Céim truaillithe | 2 |
| Modh ceangail | Input / output and power supply: Detachable spring cage termina l blocksRS-485: Detachable spring-cage terminal blockUSB: Mini-B male |
| Caighdeáin ghaolmhara | IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851 |
| Feidhm idirghlasála | Incorporated |
| Airde oibriúcháin | 2,000 m6561.680 ftor less(Note) Do not use or store this device in a pressurized environment beyond the atmospheric pressure at sea level. |
| Friotaíocht chreathadh | 5 to 8.4 Hz frequency, 3.5 mm0.138 inhalf amplitude, 8.4 to 150 Hz frequency, Max. acceleration 9.8 m/s2(1 G), in X, Y and Z directions for two hours each (IEC / EN 60068-2-6) |
| Feidhm socraithe loighce | Input mode, control mode, output mode, reset mode, auxiliary ou tput mode |
| Catagóir voltais iomarcach | II |
| Aschur táscaire múchta | Semiconductor photo MOS relay output x 1- Maximum load current: 60 mA- Supply voltage: Same as the voltage of the power supply for internal- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition) |
| Feidhm scaoilte glasála | Incorporated |
| Feidhm roghnúcháin loighce | No.0: Customization controlNo.1: Overall stop controlNo.2: Parallel muting controlNo.3: Sequential muting controlNo.4: Partial stop control 1No.5: Partial stop control 2No.6: Two-hand controlNo.7: OR controlNo.8: Operation mode selection control |
| Ionchur sábháilteachta (IN1 go IN8) | 2 inputs x 4, Rated voltage: Same as the voltage of the power supply for internal |
| Caighdeáin is infheidhme: EMC | IEC 61000-6-2, IEC 61326-3-1, EN 55011 |
| Am tosaithe tar éis cumhacht a chur air | 2 sec. or less |
| Caighdeáin is infheidhme: Sábháilteacht | IEC 61508-1 to 3, EN 61508-1 to 3 (SIL3), ISO 13849-1:2015 (Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061 (SILCL3), UL 61010-1, UL 61010-2-201, UL 1998 |
| Aschur rialaithe (OUT1 go OUT4) | PNP open-collector transistor with 2 outputs x 2- Maximum source current: 300 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition) |
| Feidhm chumarsáide (MODBUS RTU) | Interface: RS-485Protocol: MODBUS RTUMaximum transmission distance: 100 m328.084 ftMaximum number of units that can be connected: 8 units (slaves) |
| Feidhm monatóireachta gléas seachtrach | Incorporated |
| Ionchur sábháilteachta (IN1 go IN8): Leibhéal AR | Input voltage: 18 VInput current: 3.5 mA |
| Aschur táscaire múchta: Mód aschuir | ON when muting / override |
| Ionchur sábháilteachta (IN1 go IN8): Leibhéal AS | Input voltage: 5 VInput current: 1.0 mA |
| Aschur táscaire múchta: Am freagartha | 10 ms or less |
| Rialacháin agus deimhnithe infheidhme | CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety)Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification, Korea's Radio Waves Act conformity registration |
| Friotaíocht chomhshaoil: Taise chomhthimpeallach | 30 to 85 % RH, Storage: 30 to 85 % RH |
| Friotaíocht chomhshaoil: Friotaíocht turraing | 147 m/s2(15 G) 11 ms in X, Y and Z directions for three times each (IEC / EN 60068-2-27) |
| Voltas soláthair: Soláthar cumhachta do sheachtrach | 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.) |
| Voltas soláthair: Soláthar cumhachta le haghaidh inmheánach | 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.) |
| Aschur rialaithe (OUT1 go OUT4): Mód aschuir | True: ONFalse: OFF |
| Ionchur sábháilteachta (IN1 go IN8): Impedance ionchuir | 4.7 KΩ approx. |
| Friotaíocht chomhshaoil: Teocht chomhthimpeallach | -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉ |
| Aschur rialaithe (OUT1 go OUT4): Am freagartha | OFF response: 10 ms or lessON response: 100 ms or less |
| Friotaíocht chomhshaoil: Céim chosanta | IP20 (IEC)(must be installed in a control panel with protectio n IP54 or higher) |
| Friotaíocht chomhshaoil: Friotaíocht inslithe | 20 MΩ, or more, with 500 V DC megger(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port) |
| Tomhaltas reatha: Soláthar cumhachta do sheachtrach | 100 mA or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.) |
| Tomhaltas reatha: Soláthar cumhachta le haghaidh inmheánach | 200 mA or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.) |
| Ionchur sábháilteachta (IN1 go IN8): Sruth ionchuir rátáilte | 5 mA approx. |
| Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta) | PNP open-collector transistor with 1 output x 4- Maximum source current: 60 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition) |
| Aschur rialaithe (OUT1 go OUT4): Feidhm moille AR | Incorporated |
| Friotaíocht chomhshaoil: Insheasmhacht voltais | 1,000 V AC for one min.(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port) |
| Aschur rialaithe (OUT1 go OUT4): Feidhm moillithe as | Incorporated |
| Aschur táscaire múchta: Cosaint gearrchiorcaid | Incorporated |
| Aschur rialaithe (OUT1 go OUT4): Cosaint gearrchiorcaid | Incorporated |
| Ionchur sábháilteachta (IN1 go IN8): Fad an stáit AR inbhraite | 10 ms or more |
| Ionchur sábháilteachta (IN1 go IN8): Fad an stáit AS neamhbhraite | 0.7 ms or less |
| Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Am freagartha | 10 ms or less |
| Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Cosaint gearrchiorcaid | Incorporated |
| Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Mód aschuir (réamhshocruithe monarchan) | AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)AUX3: Reset trigger output (ON under reset release wait condition)AUX4: Lockout output (OFF when lockout) |
| Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Mód aschuir (Is féidir aon cheann de na haschuir chúnta a shaincheapadh ag baint úsáide as an uirlis bhogearraí) | Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)Positive logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is ON)Positive logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is ON)Outputs A, B, C, and D of diagnosis results of input blocks (ON when logic is true)Outputs E, F, and G of internal logic circuit diagnostic results (ON when logic is true)Reset trigger output (ON under reset release wait condition)Lockout output (OFF when lockout)Muting indicator output (ON when muting / override)Monitor output in response to IN1 to IN8 (ON when input)No output (normally OFF) |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta