Am seirbhíse: Luan go hAoine 9:00-18:00
USFC21 - USFC21 SF-C21 PANASONIC Safety control unit for safety light curtain and other safety products, 8 inputs 24V..
I Stoc Táirge Te

USFC21

USFC21 SF-C21 PANASONIC Safety control unit for safety light curtain and other safety products, 8 inputs 24V..

$0.00 USD
i stoc
Sonraíochtaí Príomhúla
Mír: Specifications
Meáchan: Net weight: 190 g approx.Gross weight: 320 g approx.
Táirge: Safety Control Unit
Ábhar: Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
Faisnéis faoi Sholáthraithe
PANASONIC
PANASONIC
Táirgí: 4316
Seoltar laistigh de 2-3 lá gnó de ghnáth
Cáilíocht Ráthaithe
Loingseoireacht Thapa
Tacaíocht Theicniúil

Sonraíochtaí Teicniúla

Paraiméadar Luach
Mír Specifications
Meáchan Net weight: 190 g approx.Gross weight: 320 g approx.
Táirge Safety Control Unit
Ábhar Main unit enclosure: Polycarbonate / ABS polymer alloyEnclosure: Polycarbonate
PFHD/ MTTFD 9.73 x 10−10/ 100 years or more
Uimhir Chuid SF-C21
Fad cábla 100 m328.084 ftor less
Ainm an táirge Safety Control Unit SF-C21
Uimhir Táirge SF-C21
Céim truaillithe 2
Modh ceangail Input / output and power supply: Detachable spring cage termina l blocksRS-485: Detachable spring-cage terminal blockUSB: Mini-B male
Caighdeáin ghaolmhara IEC 60947-1, IEC 60947-5-1, IEC 60947-5-2, IEC 60947-5-5, IEC 60947-5-8, IEC 61496-1, IEC TS 62046, ISO 13851
Feidhm idirghlasála Incorporated
Airde oibriúcháin 2,000 m6561.680 ftor less(Note) Do not use or store this device in a pressurized environment beyond the atmospheric pressure at sea level.
Friotaíocht chreathadh 5 to 8.4 Hz frequency, 3.5 mm0.138 inhalf amplitude, 8.4 to 150 Hz frequency, Max. acceleration 9.8 m/s2(1 G), in X, Y and Z directions for two hours each (IEC / EN 60068-2-6)
Feidhm socraithe loighce Input mode, control mode, output mode, reset mode, auxiliary ou tput mode
Catagóir voltais iomarcach II
Aschur táscaire múchta Semiconductor photo MOS relay output x 1- Maximum load current: 60 mA- Supply voltage: Same as the voltage of the power supply for internal- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Feidhm scaoilte glasála Incorporated
Feidhm roghnúcháin loighce No.0: Customization controlNo.1: Overall stop controlNo.2: Parallel muting controlNo.3: Sequential muting controlNo.4: Partial stop control 1No.5: Partial stop control 2No.6: Two-hand controlNo.7: OR controlNo.8: Operation mode selection control
Ionchur sábháilteachta (IN1 go IN8) 2 inputs x 4, Rated voltage: Same as the voltage of the power supply for internal
Caighdeáin is infheidhme: EMC IEC 61000-6-2, IEC 61326-3-1, EN 55011
Am tosaithe tar éis cumhacht a chur air 2 sec. or less
Caighdeáin is infheidhme: Sábháilteacht IEC 61508-1 to 3, EN 61508-1 to 3 (SIL3), ISO 13849-1:2015 (Category 4, PLe), IEC 61131-2, IEC 61010-2-201, IEC 62061 (SILCL3), UL 61010-1, UL 61010-2-201, UL 1998
Aschur rialaithe (OUT1 go OUT4) PNP open-collector transistor with 2 outputs x 2- Maximum source current: 300 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Feidhm chumarsáide (MODBUS RTU) Interface: RS-485Protocol: MODBUS RTUMaximum transmission distance: 100 m328.084 ftMaximum number of units that can be connected: 8 units (slaves)
Feidhm monatóireachta gléas seachtrach Incorporated
Ionchur sábháilteachta (IN1 go IN8): Leibhéal AR Input voltage: 18 VInput current: 3.5 mA
Aschur táscaire múchta: Mód aschuir ON when muting / override
Ionchur sábháilteachta (IN1 go IN8): Leibhéal AS Input voltage: 5 VInput current: 1.0 mA
Aschur táscaire múchta: Am freagartha 10 ms or less
Rialacháin agus deimhnithe infheidhme CE Marking (Machinery Directive, EMC Directive, RoHS Directive), UKCA Marking [Supply of Machinery (Safety)Regulations, EMC Regulations, RoHS Regulations], TÜV SÜD certification, Korea's Radio Waves Act conformity registration
Friotaíocht chomhshaoil: Taise chomhthimpeallach 30 to 85 % RH, Storage: 30 to 85 % RH
Friotaíocht chomhshaoil: Friotaíocht turraing 147 m/s2(15 G) 11 ms in X, Y and Z directions for three times each (IEC / EN 60068-2-27)
Voltas soláthair: Soláthar cumhachta do sheachtrach 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Voltas soláthair: Soláthar cumhachta le haghaidh inmheánach 24 V DC+10-15% Ripple P-P10 % or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Aschur rialaithe (OUT1 go OUT4): Mód aschuir True: ONFalse: OFF
Ionchur sábháilteachta (IN1 go IN8): Impedance ionchuir 4.7 KΩ approx.
Friotaíocht chomhshaoil: Teocht chomhthimpeallach -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed), Storage: -25 to +60 ℃-13 to +140 ℉
Aschur rialaithe (OUT1 go OUT4): Am freagartha OFF response: 10 ms or lessON response: 100 ms or less
Friotaíocht chomhshaoil: Céim chosanta IP20 (IEC)(must be installed in a control panel with protectio n IP54 or higher)
Friotaíocht chomhshaoil: Friotaíocht inslithe 20 MΩ, or more, with 500 V DC megger(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Tomhaltas reatha: Soláthar cumhachta do sheachtrach 100 mA or less(Note) "Power supply for external" is the power supply for control output / auxiliary output. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Tomhaltas reatha: Soláthar cumhachta le haghaidh inmheánach 200 mA or less(Note) "Power supply for internal" is the power supply for safety input. The power supplies for internal and external are insulated.(Note) The power supply unit connected to this device must satisfy the conditions below.- Output voltage within 20.4 V to 26.4 V DC (Ripple P-P: 10 % or less.)- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Directive and Low-voltage Directive (In case CE Marking conformity is required.)- Power supply unit conforming to the Low-voltage Directive and with an output of 100 VA or less- Power supply unit SELV (safety extra low voltage) / PELV (protected extra low voltage) conforming to the EMC Regulations and Low-voltage Regulations (In case UKCA Marking conformity is required.)- Power supply unit with an output holding time of 20 ms or more.- Power supply unit corresponding to CLASS 2 (In case C-TÜV US Listing Mark conformity is required.)
Ionchur sábháilteachta (IN1 go IN8): Sruth ionchuir rátáilte 5 mA approx.
Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta) PNP open-collector transistor with 1 output x 4- Maximum source current: 60 mA / output- Applied voltage: Same as the voltage of the power supply for external- Residual voltage: 2.5 V or less- Leakage current: 100 μA or less (Including power supply OFF condition)
Aschur rialaithe (OUT1 go OUT4): Feidhm moille AR Incorporated
Friotaíocht chomhshaoil: Insheasmhacht voltais 1,000 V AC for one min.(All inputs connected together - USB port, all inputs connected together - RS-485 port, USB port - RS-485 port, between all supply terminals connected together and enclosure, all outputs connected together - all input connected together, all outputs connected together - USB port, all outputs connected together - RS-485 port)
Aschur rialaithe (OUT1 go OUT4): Feidhm moillithe as Incorporated
Aschur táscaire múchta: Cosaint gearrchiorcaid Incorporated
Aschur rialaithe (OUT1 go OUT4): Cosaint gearrchiorcaid Incorporated
Ionchur sábháilteachta (IN1 go IN8): Fad an stáit AR inbhraite 10 ms or more
Ionchur sábháilteachta (IN1 go IN8): Fad an stáit AS neamhbhraite 0.7 ms or less
Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Am freagartha 10 ms or less
Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Cosaint gearrchiorcaid Incorporated
Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Mód aschuir (réamhshocruithe monarchan) AUX1: Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)AUX2: Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)AUX3: Reset trigger output (ON under reset release wait condition)AUX4: Lockout output (OFF when lockout)
Aschur cúnta (AUX1 go AUX4) (Aschur neamhshábháilteachta): Mód aschuir (Is féidir aon cheann de na haschuir chúnta a shaincheapadh ag baint úsáide as an uirlis bhogearraí) Negative logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is OFF)Negative logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is OFF)Positive logic of OUT1 / OUT2 (ON when OUT1 / OUT2 is ON)Positive logic of OUT3 / OUT4 (ON when OUT3 / OUT4 is ON)Outputs A, B, C, and D of diagnosis results of input blocks (ON when logic is true)Outputs E, F, and G of internal logic circuit diagnostic results (ON when logic is true)Reset trigger output (ON under reset release wait condition)Lockout output (OFF when lockout)Muting indicator output (ON when muting / override)Monitor output in response to IN1 to IN8 (ON when input)No output (normally OFF)

Cur Síos ar an Táirge

Control unit for barriers and other safety products, Cat. 4(Ple) and SIL3, 4 inputs, 2 outputs, 8 pre-established logics according to cat regulations. 4 (Ple) and 1 customizable logic, self-diagnostic
Príomhghnéithe
  • Cáilíocht ghrád tionsclaíoch
  • Comhlíontach le RoHS
  • Deimhnithe CE
  • Barántas 1 bhliain

Doiciméid Táirge

Bileog Sonraí

Sonraíochtaí teicniúla agus sonraí feidhmíochta

Lámhleabhar Úsáideora

Treoir suiteála agus oibríochta

Top