| Paraiméadar | Luach |
|---|---|
| Mír | Specifications |
| Cineál | NPN output |
| Meáchan | Net weight: 140 g approx. |
| Sonraí | Controller (NPN output) |
| Táirge | Ultra-compact Laser Collimated Beam Sensor |
| Ábhar | Enclosure: Polybutylene terephthalateTransparent cover: Polycarbonate |
| Cábla I/O | 0.09 mm210-core composite cable, 2 m6.562 ftlong |
| Uimhir Chuid | HL-AC1 |
| Athshocraigh an t-ionchur | 0 V connection: EffectiveOpen: Ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Ainm an táirge | Ultra-compact Laser Collimated Beam Sensor HL-T1 |
| Ionchur ama | 0 V connection: EffectiveOpen: Ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Aschur líneach | Current / voltage output switchable (Note)-During current output: 4 to 20 mA/F.S., Maximum load resistance: 300 Ohm-During voltage output: plus or minus 4 V/F.S., Output impedance 100 Ohm(In the monitor focus function, it can also be set at plus or minus 5 V, 0 to 5 V, etc.)(Note) Switching between current and voltage is accomplished by a switch on the bottom of the controller. |
| Príomhfheidhmeanna | ・Measured value display・Setting value, light amount value resolution display・Standard received light setting・Automatic scaling・Scaling・Display reverse・ECO display・Display digits limitation・Sample hold・Peak hold・Bottom hold・Peak to peak hold・Self peak hold・Self bottom hold・Zero reset・Initial reset・ON-delay timer・OFF-delay timer・One-shot timer・Differentiation・Sensitivity selection・Threshold value direct setting・Positioning teaching・2-point teaching・Automatic teaching・Hysteresis width variability・Monitor focus・Non-measuring time setting・(A – B) calculation(Note:The calculation unit is necessary.)・(A + B) calculation(Note:The calculation unit is necessary.)・Mutual interference prevention (Note:The calculation unit is necessary.)・Laser deterioration detection・Key lock・Zero reset memory |
| Uimhir Táirge | HL-AC1 |
| Voltas soláthair | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Ionchur léasair AS | 0 V connection: Laser emission haltOpen: Laser emission-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Timthriall tomhais | 150 micro s |
| Céim truaillithe | 3 (industrial environment) |
| Ionchur athshocraithe nialasach | 0 V connection: Zero reset operatesOpen: Zero reset ineffective-Applied voltage: 30 V DC or less (leak current: 0.1 mA or less) |
| Tomhaltas reatha | 190 mA or less (when connected to the sensor head) |
| Síneadh cábla I/O | Extension up to total 10 m32.808 ftis possible, with 0.09 mm2or more, cable.(Note) If the extension cable is longer than 10 m32.808 ft, then it will not qualify for CE marking. |
| Taispeántas fo-dhigiteach | 5 digit yellow LED display[RUN mode: Either the resolution or laser beam reception amount will be displayed. THR mode: The threshold value will be displayed., Reverse mode: The display orientation will be reversed.] |
| Príomhthaispeántas digiteach | 5 digit red LED display[RUN mode: Either the measured value (mm) or the hold value will be displayed. Reverse mode: The display orientation will be reversed.] |
| Friotaíocht inslithe | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Ceann braiteora infheidhme | HL-T1001A/T1001F, HL-T1005A/T1005F, HL-T1010A/T1010F |
| Inmharthanacht voltais | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Táscairí: Cumasaigh (ENABLE) | Green LED (lights up during normal operation) |
| Táscairí: Aschuir bhreithiúnais | HIGH: Orange LED (lights up when measured value > HIGH threshold value)PASS: Green LED (lights up when HIGH threshold value >= measured value >= LOW threshold value)LOW: Yellow LED (lights up when LOW threshold value > measured value) |
| Táscairí: Athshocrú nialasach (ZERO) | Green LED (lights up when the zero reset function is enabled) |
| Meánráta samplála inchoigeartaithe | 1 / 2 / 4 / 8 / 16 / 32 / 64 / 128 / 256 / 512 / 1,024 / 2,048 / 4,096(Note) The judgment output and linear output and linear output response time is calculated by (Measuring cycle) x (Set average sampling rate + 1). |
| Comhlíonadh treoir marcáil CE | EMC Directive, RoHS Directive |
| Aschuir bhreithiúnais (ARD, PAS, ÍSEAL) | NPN open-collector transistor-Maximum sink current: 50 mA-Applied voltage: 30 V DC or less (between judgment output and 0 V)-Residual voltage: 1.2 V or less (at 50 mA sink current) |
| Táscairí: Astaíocht léasair (LD ON) | Green LED (lights up during laser emission) |
| Friotaíocht chomhshaoil: Taise chomhthimpeallach | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Friotaíocht chomhshaoil: Friotaíocht turraing | 300 m/s2acceleration (30 G approx.) in X, Y and Z directions three times each |
| Aschur líneach: Saintréithe teochta | plus or minus 0.2 % F.S./℃(Note) These are the temperature characteristics of the linear output when the sensor head is connected. |
| Friotaíocht chomhshaoil: Teocht chomhthimpeallach | 0 to +50 ℃+32 to +122 ℉(No dew condensation allowed), Storage: -25 to +65 ℃-13 to +149 ℉ |
| Friotaíocht chomhshaoil: Friotaíocht chreathadh | 10 to 150 Hz frequency, 0.7 mm0.028 indouble amplitude in X, Y and Z directions for 80 min. |
| Aschuir bhreithiúnais (ARD, PASS, ÍSEAL): Oibríocht aschuir | HIGH: ON when measured value > HIGH threshold valuePASS: ON when HIGH threshold value >= measured value >= LOW threshold valueLOW: ON when LOW threshold value > measured value |
| Aschuir bhreithiúnais (ARD, PASS, ÍSEAL): Líon na n-aschur | HIGH / PASS / LOW 3 values output |
| Aschuir bhreithiúnais (ARD, PAS, ÍSEAL): Catagóir úsáide | DC-12 or DC-13 |
| Aschuir bhreithiúnais (ARD, PASS, ÍSEAL): Cosaint gearrchiorcaid | Incorporated |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta