Am seirbhíse: Luan go hAoine 9:00-18:00
UHGS1010AC - UHGS1010AC HG-S1010-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator..
I Stoc Táirge Te

UHGS1010AC

UHGS1010AC HG-S1010-AC PANASONIC HG-S Sensor for measurement by contact. Head sensor with pneumatic actuator..

$0.00 USD
i stoc
Sonraíochtaí Príomhúla
Mír: Specifications
Nóta: Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Stróc: 10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Meáchan: Net weight: 80 g approx.
Faisnéis faoi Sholáthraithe
PANASONIC
PANASONIC
Táirgí: 4316
Seoltar laistigh de 2-3 lá gnó de ghnáth
Cáilíocht Ráthaithe
Loingseoireacht Thapa
Tacaíocht Theicniúil

Sonraíochtaí Teicniúla

Paraiméadar Luach
Mír Specifications
Nóta Where measurement conditions are not specified, the conditions used were as follows: standard type measurement probe (HG-SS10C), ambient temperature of +20 ℃+68 ℉, and a clean atmosphere where water, oil, other liquids or dust does not come in contact with the equipment.
Stróc 10.5 mm0.413 inor more(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Meáchan Net weight: 80 g approx.
Sonraí Air-driven type10 mm0.394 intype General purpose
Táirge Contact-Type Digital Displacement Sensor
Ábhar Body: Zinc, Holder: Stainless steel, Spindle: Tool steel, Probe (Note): Brass (body) / Ceramic (ball),, Air tube clamp: S60CM(Note) : The probe is also available as an option.
Gabhálas Sensor head fastening wrench: 1 pc., Mounting nut: 1 pc., Seal cap: 1pc, Air tube clamp: 1 pc.
Rún 0.5 μm0.02 mil
Uimhir Chuid HG-S1010-AC
Ainm an táirge Contact-Type Digital Displacement Sensor HG-S
Sreabhán inúsáidte Clean air (Dew point temperature: -10 ℃+14 ℉or less)
Ráta samplála 1 ms
Uimhir Táirge HG-S1010-AC
Feadán infheidhme Outside diameter: ø4 mmø0.157 in/ Inside diameter: ø2.5 mmø0.098 in
Fórsa a thomhas ・Measuring force changes with the air pressure used. Removing the seal cap enables the product to be used as the low measuring force type.・For the relationship between supplied air pressure and measuring force or between measuring force and pushed spindle position, see the figures below. For upward mount without a seal cap, subtract 0.2 N from the measuring force. For side mount, subtract 0.1 N from the measuring force. The following figures are only typical examples, and these relationships differ depending on the assembly accuracy of the product or the abrasion status of sealing materials.
Raon tomhais 10 mm0.394 in(Note) : The position that represents "0" as an absolute value is a position where the spindle is pushed further down from the bottom dead point by 0.1 mm0.004 inor more. The term "stroke" indicates the total stroke length from the bottom dead point to the top dead point.
Modh talmhaithe Capacitor grounding
Céim truaillithe 2
Feidhm mhalartaithe te Incorporated
Airde oibriúcháin 2,000 m6561.68 ftor less(Note) : Do not use or store in an environment that has been pressurized to an air pressure higher than the atmospheric pressure at 0 m.
Táscaire oibríochta Equipped (2-color LED: Orange / Green)
Méid diall na leideanna 35 μm1.378 mil(typical value)
Rialaitheoir infheidhme HG-SC101(-P), HG-SC111(-P), HG-SC112(-P), HG-SC113(Note) : Be sure to use the sensor in combination with an HG-SC□ controller manufactured in or after February 2019.
Friotaíocht inslithe 100 MΩ or more at 250 V DC
Comhlíonadh rialála CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations)
Raon brú oibre 0.14 to 0.16 MPaWith no seal cap mounted : 0.035 to 0.045 MPa
Cruinneas tásc (PP) Full range: 2.0 μm0.079 milor lessLimited range: 1.0 μm0.039 milor less(any 60 μm2.362 mil)
Modh braite suímh Optical absolute linear encoder method
Cumas chun brú a sheasamh 0.2 MPa
Friotaíocht chomhshaoil: Cosaint IP67 (IEC)With no seal cap mounted : -(Note) : Protective structure is not applicable when the sealing portions have deteriorated or become damaged. The protection level is zero when the seal cap is removed.
Friotaíocht chomhshaoil: Taise chomhthimpeallach 35 to 85 % RH, Storage: 35 to 85 % RH
Friotaíocht chomhshaoil: Friotaíocht turraing 1,960 m/s2acceleration in X, Y, and Z directions three times each
Friotaíocht chomhshaoil: Teocht chomhthimpeallach -10 to +55 ℃+14 to +131 ℉(No dew condensation or icing allowed),Storage: -20 to +60 ℃-4 to +140 ℉
Friotaíocht chomhshaoil: Friotaíocht chreathadh 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude (10 to 58 Hz), maximum acceleration 196 m/s2, (58 to 150 Hz) in X, Y, and Z directions for two hours each

Cur Síos ar an Táirge

HG-S - Contact measurement sensor. Sensor head with pneumatic actuator. Resolution 0.5μm. Precision 2μm. Range 10mm
Príomhghnéithe
  • Cáilíocht ghrád tionsclaíoch
  • Comhlíontach le RoHS
  • Deimhnithe CE
  • Barántas 1 bhliain

Doiciméid Táirge

Bileog Sonraí

Sonraíochtaí teicniúla agus sonraí feidhmíochta

Lámhleabhar Úsáideora

Treoir suiteála agus oibríochta