Sonraíochtaí Príomhúla
Mír: Specifications
Nóta: (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
Meáchan: Net weight: 30 g approx., Gross weight: 125 g approx.
Sonraí: Discrete wire type
Faisnéis faoi Sholáthraithe
PANASONIC
PANASONIC
Táirgí: 4316
Seoltar laistigh de 2-3 lá gnó de ghnáth
Cáilíocht Ráthaithe
Loingseoireacht Thapa
Tacaíocht Theicniúil

Sonraíochtaí Teicniúla

Paraiméadar Luach
Mír Specifications
Nóta (Note:)measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20℃ +68℉.
Meáchan Net weight: 30 g approx., Gross weight: 125 g approx.
Sonraí Discrete wire type
Taispeáin 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
Táirge Dual Display Digital Pressure Sensor [For Gas]
Ábhar Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Cosaint IP40(IEC)
Gabhálais CN-14A-C2 (Connector attached cable 2 m6.562 ft): 1 pc.
Uimhir Chuid DP-102ZL3-M-P
Fad cábla Total length up to 20 m65.617 ft(Condition of CE compliance less than 20 m65.617 ft)is possible with 0.3 mm2, or more, cable.
Ainm an táirge Dual Display Digital Pressure Sensor [For Gas] DP-100L
Calafort brú M5 female thread
Uimhir Táirge DP-102ZL3-M-P
Voltas soláthair 12 to 24 V DC ±10 % Ripple P-P 10 % or less
Taise chomhthimpeallach 35 to 85 % RH, Storage: 35 to 85 % RH
Sreabhán infheidhme Non-corrosive gas
Táscaire aschuir Orange LED(Output operation indicator 1: Flashes during IO-Link communication, Lights up when the control output is ON during non-IO-Link communication (synchronized with the output operation indicator 2)Output operation indicator 2: Lights up when the control output is ON)
Friotaíocht turraing 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each
Cineál brú Gauge pressure
Modh ceangail Connector
Tomhaltas cumhachta Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
Socraigh raon brú -0.101 to +1.010MPa
Teocht chomhthimpeallach -10 to +50℃+14 to +122 ℉(No dew condensation or icing allowed), Storage: -10 to +60℃+14 to +140 ℉
Aschur rialaithe (DO) PNP open-collector transistor•Maximum source current: 50 mA• Applied voltage: 30 V DC or less (between output and +V)• Residual voltage: 2 V or less (at 50 mA source current)
Raon brú rátáilte -0.100 to +1.000 Mpa
Friotaíocht chreathadh 10 to 500 Hz frequency, 3 mm0.118 indouble amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each(when panel or flat attachment is mounted: 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Friotaíocht inslithe 50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
Inmharthanacht voltais 1,000 V AC for one min. between all supply terminals connected together and enclosure
Inmharthanacht brú 1.5MPa
Saintréithe teochta Within ±1 % F.S.(at +20℃+68℉)
Aschur rialaithe (DO): Histéiréis Minimum 1 digit (variable)
Aschur rialaithe (DO): In-athdhéantacht ±0.2 % F.S. (within ±2 digits)
Aschur rialaithe (DO): Am freagartha 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Taispeáint: Raon brú intaispeánta -0.101 to +1.010MPa
Aschur cumarsáide (C/Q): Ráta Baud COM3 (230.4 kbps)(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Aschur rialaithe (DO): Oibriú aschuir N.O./N.C. (selectable by key operation)
Aschur cumarsáide (C/Q): Sonraí próisis 4 byte(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Comhlíonadh rialála agus deimhniú CE Marking (EMC Directive, RoHS Directive), UKCA Marking (EMC Regulations, RoHS Regulations), UL/c-UL Certification
Aschur rialaithe (DO): Cosaint gearrchiorcaid Incorporated
Aschur cumarsáide (C/Q): Am timthriall íosta 1.0ms(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Aschur cumarsáide (C/Q): cumarsáid IO-Link IO-Link Specification V1.1(Note:)When the sensor is used as an ordinary sensor, the communication output (C/Q) provides the same output operation as the control output (DO).
Aschur rialaithe (DO): Oibríocht aschuirMóid aschuir EASY mode / Hysteresis mode / Window comparator mode

Cur Síos ar an Táirge

DP-100L Series. Digital pressure controller, -1 to 10bar, short M5 female threaded pressure port, 2m cable, IO Link connection, PNP