| Paraiméadar | Luach |
|---|---|
| Ue | |
| DC | Resistive load (DC-12) |
| I.e. | AC |
| B10D | 2,000,000(ISO 13849-1 Annex C Table C.1) |
| Mír | Specifications |
| Cábla | UL style 2464, No.22 AWG 12-core |
| Meáchan | Approx. 680 g |
| Táirge | Safety door switch with key |
| Ábhar | Enclosure : PA66 |
| Cosaint | IP 65 (IEC 60529) |
| Uimhir Chuid | SG-B2-K2CD-5 |
| Fad cábla | 5m16.404 ft |
| Ainm an táirge | Safety door switch with key SG-B2 |
| Uimhir Táirge | SG-B2-K2CD-5 |
| Fórsa idirghlasála | 1,400 N min. (GS-ET-19)(Note)(500 N min. : SG-K24 actuator)(Note): The actuator locking strength is rated at 1,400 N of static load. Do not apply a load higher than the rated value. When a higher load is expected to work on the actuator, provide an additional system consisting of another safety switch without lock (such as the SG-A1 safety switch) or a sensor to detect door opening and stop the machine. |
| Friotaíocht turraing | Malfunction : 100 m/s2, Destruction : 1,000 m/s2 |
| Friotaíocht teagmhála | 700 mΩ max. (initial value, 5 m16.404 ftcable) |
| Socrú teagmhála | |
| Minicíocht oibriúcháin | 900 operations/hour |
| Caighdeáin is infheidhme | EN 1088, IEC 60947-5-1, EN 60947-5-1,GS-ET-19, UL 508, CSA C22.2 No.14 |
| Fórsa oscailte díreach | 80 N min. |
| Seasamh bainte eochrach | C(removable in LOCK position) |
| Friotaíocht chreathadh | Malfunction : 10 to 55 Hz, half amplitude 0.35 mm0.014 inDestruction : 30 Hz, half amplitude 1.5 mm0.059 in |
| Treoracha infheidhme | Machinery directive (2006/42/EC)Low voltage directive (2006/95/EC) |
| Taisteal oscailte díreach | 11 mm0.433 inmin. (actuator : SG-K21)12 mm0.472 inmin. (for other actuators) |
| Marthanacht leictreach | 100,000 operations min. (AC-12, 250 V 1 A)1,000,000 operations min. (AC/DC 24 V 100 mA)(900 operations/hour) |
| Marthanacht mheicniúil | 1,000,000 operations min. (GS-ET-19)Rear unlocking button : 3,000 operations min. (Type SG-B2-□-L5) |
| Sruth teirmeach (Ith) | ・2.5 A・Ambient temperature :-25 to +60 ℃-13 to +140 ℉: 2.5 A max.+60 to +65 ℃+140 to +149 ℉: 1.5 A max.+65 to +70 ℃+149 to +158 ℉: 1.0 A max. |
| Ualach ionduchtach (AC-15) | - |
| Ualach ionduchtach (DC-13) | 2.3A |
| Luas oibriúcháin an achtóra | 0.05 to 1.0 m/sec. |
| Eochair: Fórsa oscailte díreach | 0.6 N・m min. |
| Eochair: Neart teanntachta eochair | 1.0 N・m min. |
| Eochair: Céim oscailte dírí | 60°min. |
| Eochair: Marthanacht mheicniúil | 100,000 operations min. |
| Voltas inslithe rátáilte (Ui) | 250 V(Note): Ratings approved by UL, c-UL : 125 V |
| Eochair: Marthanacht oibriúcháin eochair | 10,000 operations min. |
| Eochair: Sonraíochtaí oibriúcháin | 2 positions |
| Coinníoll oibriúcháin: Airde | 2,000 m6,561.68 ftmax. |
| Rang cosanta turraing leictreach | Class II (IEC 61140)(Note), 回(double-insulated)(Note): Basic insulation of 2.5 kV impulse withstand voltage is ensured between different contact circuits.When both SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other circuits (such as 230 V AC circuits) are used for the solenoid power and contact circuits at the same time, the SELV or PELV requirements are not met any more. |
| Gléas cosanta gearrchiorcaid | Use 250 V / 10 A fast acting type fuse |
| Voltas seasmhachta impulse (Uimp) | 2.5 kV |
| Sruth gearrchiorcaid coinníollach | 50 A (250 V) |
| Coinníoll oibriúcháin: Taise chomhthimpeallach | 45 to 85 % RH |
| Coinníoll oibriúcháin: Céim truaillithe | 3 (Inside 2) |
| Caighdeáin infheidhme: Caighdeáin úsáide | IEC 60204-1, EN 60204-1 |
| Coinníoll oibriúcháin: Teocht chomhthimpeallach | -25 to +70 ℃-13 to +158 ℉(No dew condensation or icing allowed)Storage : -40 to +80 ℃-40 to +176 ℉ |
| Voltas oibriúcháin rátáilte (Ue) / Sruth oibriúcháin rátáilte (Ie) | Ue30V125V250VIeACResistive load (AC-12)-2.5A1.5AInductive load (AC-15)-1.5A0.75ADCResistive load (DC-12)2.5A1.1A0.55AInductive load (DC-13)2.3A0.55A0.27A |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta