| PFHD | 1.66 × 10-10(Note:Probability of dangerous failure per hour) |
| MTTFD | 100 years or more(Note:Mean time to dangerous failure (in years)) |
| Meáchan | Net weight: 250 g approx. |
| Sonraí | Applicantion expansion unit for the SF4B series |
| Táirge | Exclusive Control Unit for Safety Light Curtain |
| Ábhar | Enclosure: ABS |
| Uimhir Chuid | SF-C14EX |
| Ainm an táirge | Exclusive Control Unit for Safety Light Curtain SF-C10 |
| Voltas cumhachta | 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Uimhir Táirge | SF-C14EX |
| Taise chomhthimpeallach | 30 to 85 % RH, Storage: 30 to 95 % RH |
| Catagóir rialaithe | ISO 13849-1 (EN ISO 13849-1, JIS B 9705-1) compliance up to Category 4, PLe standards |
| Friotaíocht turraing | 30 G acceleration in X, Y and Z directions three times each |
| Aschur lampa múchta | Applicable muting lamp: 24 V DC, 3.6 to 30 W (L1, L2 of each unit) |
| Teocht chomhthimpeallach | -10 to +55 ℃+14 to +131℉(No dew condensation or icing allowed),Storage: -25 to +70 ℃-13 to +158 ℉ |
| Críochfort nasc | Detachable spring-cage terminal |
| Tomhaltas reatha | 0.2 A or less (Excluding Safety light curtain and other external connecting device) |
| Friotaíocht chreathadh | 10 to 55 Hz frequency, 0.35 mm0.014 indouble amplitude in X, Y and Z directions for two hours each |
| Friotaíocht inslithe | 20 MOhm , or more, with 500 V DC megger between all supply terminals connected together and enclosure |
| Caighdeáin is infheidhme: An tSeapáin | JIS B 9704-1 (Type 4), JIS B 9705-1 (Category 4, PLe) |
| Comhlíonadh treoir marcáil CE | Machinery Directive, EMC Directive, RoHS Directive |
| Caighdeáin is infheidhme: An Eoraip (AE) | EN 55011, EN ISO 13849-1 (Category 4, PLe) |
| Cuirtíní solais sábháilteachta incheangailte | SF4B / SF4B-Gseries(Note:The handy-controllerSFB-HC(optional) cannot be used withSF-C14EX-01.) |
| Caighdeáin is infheidhme: Meiriceá Thuaidh | ANSI/UL 61496-1 (Type 4), UL 1998 (Class 2) |
| Aschur lampa múchta: Ciorcad cosanta | Incorporated |
| Caighdeáin infheidhme: Caighdeán idirnáisiúnta | IEC 61496-1 (Type 4), IEC 61496 (Type 4),ISO 13849-1 (Category 4, PLe) |
| Friotaíocht chomhshaoil: Céim chosanta | Enclosure: IP40Terminal: IP20 |
| Friotaíocht chomhshaoil: Voltas neart tréleictreach | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Aschuir sábháilteachta (aschur sábháilteachta 1, aschur sábháilteachta 2, aschur sábháilteachta 3) | PNP open-collector transistor 2 outputs × 3 or NPN open-collector transistor 2 outputs × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 200 mA・Applied voltage: same as supply voltage(between the safety output and +V)・Residual voltage: 2 V or less (at 200 mA source current)<When NPN output is selected>・Maximum sink current: 200 mA・Applied voltage: same as supply voltage(between the safety output and 0 V)・Residual voltage: 2 V or less (at 200 mA sink current) |
| Aschuir sábháilteachta (aschur sábháilteachta 1, aschur sábháilteachta 2, aschur sábháilteachta 3): Am freagartha | OFF response: 14 ms or less (Safety output 1 and 2: including the response time of the Safety light curtain)ON response: 90 ms or less (auto-reset) / 140 ms or less (manual reset) (Note)(Note) The auto-reset cannot be used with safety output 3. |
| Aschuir chúnta (Aschur cúnta 1, Aschur cúnta 2, Aschur cúnta 3, Aschur cúnta 4) | PNP open-collector transistor × 3 or NPN open-collector transistor × 3 (selectable using a slider switch)<When PNP output is selected>・Maximum source current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and +V)・Residual voltage: 2 V or less (at 60 mA source current)<When NPN output is selected>・Maximum sink current: 60 mA・Applied voltage: same as supply voltage(between the auxiliary output and 0 V)・Residual voltage: 2 V or less (at 60 mA sink current) |
| Aschuir sábháilteachta (Aschur sábháilteachta 1, Aschur sábháilteachta 2, Aschur sábháilteachta 3): Mód oibríochta (Oibríocht aschuir) | Safety output 1: ON when the safety light curtain is in light receiving condition, OFF when the safety light curtain is in light interrupted condition (Note 3)Safety output 2: ON when the safety light curtain is in light receiving condition or the muting function is validOFF when the safety light curtain is in light interrupted condition and the muting function is invalid (Note 3)Safety output 3: ON when the emergency stop is invalid, OFF when the emergency stop is valid |
| Aschuir sábháilteachta (Aschur sábháilteachta 1, Aschur sábháilteachta 2, Aschur sábháilteachta 3): Ciorcad cosanta (Cosaint gearrchiorcaid) | Incorporated |
| Aschuir chúnta (Aschur cúnta 1, Aschur cúnta 2, Aschur cúnta 3, Aschur cúnta 4): Mód oibríochta (Oibríocht aschuir) | Auxiliary output 1: ON when the muting function is invalid, OFF when the muting function is validAuxiliary output 2: ON when the override function is invalid, OFF when the override function is validAuxiliary output 3: ON when the muting lamp is normal, OFF when the muting lamp is errorAuxiliary output 4: ON when the light curtain is in light interrupted condition, OFF when the light curtain is in light receiving condition(Note:The auxiliary output incorporated in theSF4Bseries is output.) |
| Aschuir chúnta (Aschur cúnta 1, Aschur cúnta 2, Aschur cúnta 3, Aschur cúnta 4): Ciorcad cosanta (Cosaint gearrchiorcaid) | Incorporated |