| Paraiméadar | Luach |
|---|---|
| Safety door | |
| Doimhneacht | 114.5 mm |
| Turraing | 15g |
| Leithead | 22.5 mm |
| Airde | 99 mm |
| Catagóir | 4 |
| inphlugáilte | yes |
| Cineál athsheachadáin | Electromechanical relay with force-guided contacts in accordance with IEC/EN 61810-3 |
| Feidhmchlár | Emergency stop |
| Comhthuiscint | ∞ |
| Am scagaire | 5 ms (at A1 in the event of voltage dips at Us) |
| Fiús aschuir | 10 A gL/gG (Enabling current paths) |
| Cineál táirge | Safety relays |
| Snáithe scriú | M3 |
| Nóta tionóil | See derating curve |
| Cineál gléasta | DIN rail mounting |
| Am téarnaimh | 1 s (following demand of the safety function) |
| Catagóir stad | 0 |
| Aitheantas | CE-compliant |
| sruth isteach | < 3.5 A (Δt = 3 ms at Us) |
| Teaghlach táirgí | PSRclassic |
| Taispeántas stádais | LED (green) |
| Dath (Tithíocht) | yellow (RAL 1018) |
| Athbhreithniú airteagail | 06 |
| Ábhar teagmhála | AgSnO2, + 0.2 µm Au |
| Ábhar tithíochta | Polyamide |
| Airde uasta | ≤ 2000 m (Above sea level) |
| Fad stialladh | 7 mm |
| Modh ceangail | Screw connection |
| Suíomh gléasta | vertical or horizontal |
| Sruth iomlán cearnach | 72 A2(Enabling current paths) |
| Ciorcad cosanta | Surge protection; Suppressor diode |
| Tomhaltas reatha | typ. 38 mA (S12) |
| Nóta ar an iarratas | Only for industrial use |
| Céim chosanta | IP20 |
| Am scaoilte tipiciúil | 20 ms (on demand via the sensor circuit) |
| Caighdeáin/rialacháin | DIN EN 60947-1 |
| Am freagartha tipiciúil | 100 ms (Monitored/manual start) |
| Creathadh (oibriú) | 10 Hz ... 150 Hz, 2g |
| Cineál lasctha teagmhála | 3 enabling current paths |
| Uasmhéid reatha ionsaithe | 6 A |
| Mód oibriúcháin ainmniúil | 100% operating factor |
| Leibhéal feidhmíochta (PL) | e (5 A DC13; 5 A AC15; 8760 switching cycles/year) |
| Sruth ionsúcháin, íosta | 10 mA |
| Saol seirbhíse meicniúil | approx. 107cycles |
| Tomhaltas cumhachta sna Stáit Aontaithe | typ. 1.68 W (DC) |
| Cumas lasctha íosta. | 100 mW |
| Voltas inslithe rátáilte | 250 V |
| Uasvoltas lasctha | 250 V AC/DC |
| Íosvoltas lasctha | 10 V AC/DC |
| Taispeántas voltais oibriúcháin | Green LED |
| Am tosaigh tipiciúil linn | 250 ms (when controlled via A1) |
| Trasghearradh seoltóra AWG | 24 ... 12 |
| Sruth leanúnach a theorannú | 6 A (Observe derating and load limit curve) |
| Sruth ionchuir tipiciúil ag UN | 70 mA DC (at Us) |
| Leibhéal Ionracais Sábháilteachta (SIL) | 3 |
| Trasghearradh seoltóra righin | 0.2 mm² ... 2.5 mm² |
| Voltas borrtha/insliú rátáilte | See section “Insulation coordination” |
| Teocht chomhthimpeallach (oibriú) | -20 °C ... 55 °C (observe derating) |
| Reatha soláthair rialaithe rátáilte IS | typ. 70 mA |
| Trasghearradh seoltóra solúbtha | 0.2 mm² ... 2.5 mm² |
| Uasráta cur isteach (ualach ómach) | see load limit curve |
| Raon voltais ionchuir i dtagairt do na Náisiúin Aontaithe | 0.85 ... 1.1 |
| Teocht chomhthimpeallach (stóráil/iompar) | -40 °C ... 70 °C |
| Voltas soláthair ciorcaid rialaithe rátáilte SAM | 24 V DC -15 % / +10 % |
| Íosmhéid cosanta suíomh institiúideach | IP54 |
| Voltas ag an gciorcad ionchuir/tosaithe agus aiseolais | approx. 24 V DC |
| Uasmhéid taise incheadaithe (stóráil/iompar) | 75 % (on average, 85% infrequently, non-condensing) |
| Friotaíocht uasta incheadaithe foriomlán an tseoltóra | approx. 50 Ω (Input and start circuits at US) |
| Uasmhéid taiseachas coibhneasta incheadaithe (oibríocht) | 75 % (on average, 85% infrequently, non-condensing) |
| Uasmhéid diomailt chumhachta le haghaidh riocht ainmniúil | 16.44 W (US= 26.4 V, IL² = 72 A², PTotal max= 2.04 W + 14.4 W) |
| Cumas lasctha de réir IEC 60947-5-1 | 6 A (DC13, enabling current paths) |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta