| Paraiméadar | Luach |
|---|---|
| Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque. | |
| Cineál | D7 |
| Tástálacha | DIN VDE 0627/86 |
| Leithead | 21 mm |
| Airde | 34.8 mm |
| Fad | 21 mm |
| Sraith | HC-HS |
| Ginearálta | for HC-D7 housing, axial connection 2.0 mm, Allen key |
| Feidhmchlár | Power |
| Cineál táirge | Contact insert with a fixed no. of positions |
| Nóta tionóil | To ensure correct use, installation in housing with IP54 protection or better is required |
| Sruth rátáilte | 40 A |
| Athbhreithniú airteagail | 04 |
| Trastomhas teagmhála | 4 mm |
| Ábhar teagmhála | Copper alloy |
| Soicéad heicseagánach | SW2,0 |
| Uimhriú teagmhála | 1 - 2 |
| Chasmhóiminte teannaithe | 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing) |
| Próifíl nasc | 2+PE |
| Céim an truaillithe | 3 |
| Líníocht thoisí | |
| Líon na bpost | 2 |
| Voltas borrtha rátáilte | 6 kV |
| Catagóir róvoltais | III |
| Teicneolaíocht nasctha | Axial screw connection |
| Cineál ábhar teagmhála | turned |
| Líon na dteagmhálacha cumhachta | 2 |
| Voltas rátáilte (III/3) | 400 V |
| Trasghearradh seoltóra | 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used) |
| Ábhar iompróra teagmhála | PC |
| Ábhar dromchla teagmhála | Ag |
| Timthriallta iontrála/aistarraingthe | ≥ 500 |
| Trasghearradh nasc AWG | 10 ... 8 |
| Teocht chomhthimpeallach (oibriú) | -40 °C ... 125 °C (including heating up of contacts) |
| Ceangal de réir an chaighdeáin | IEC / EN |
| Rialacháin thógála agus tástála | DIN VDE 0627/86 |
| Rátáil inadhainteachta de réir UL 94 | V0 |
| Fad stialladh na sreinge aonair | 8 mm +1 mm |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta