Am seirbhíse: Luan go hAoine 9:00-18:00
HC-HS 2-D7-EBUS - HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert
I Stoc Táirge Te

HC-HS 2-D7-EBUS

HC-HS 2-D7-EBUS 1586264 PHOENIX CONTACT Contact insert

$35.46 USD
i stoc
Sonraíochtaí Príomhúla
: Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Cineál: D7
Tástálacha: DIN VDE 0627/86
Leithead: 21 mm
Faisnéis faoi Sholáthraithe
Táirgí: 0
Seoltar laistigh de 2-3 lá gnó de ghnáth
Cáilíocht Ráthaithe
Loingseoireacht Thapa
Tacaíocht Theicniúil

Sonraíochtaí Teicniúla

Paraiméadar Luach
Note regarding axial connection technology:Only for stranded wires. The specified conductor cross sections refer to the geometric cross section of the cable used.Cables with a geometric cross section which deviates significantly from the nominal cable cross section must be checked before use.The axial connection technology connection space is designed for fine strand cables according to VDE 0295 Class 5. Deviating cable structures (e.g., Class 6 cables) must be checked before use.Assembly instructionsBefore assembly, ensure that the tapered screw is fully loosened (chamber is open). Cables must not be twisted. The wires must be pushed into the contact chamber as far as they will go (until the insulation touches the contact). Hold the wires in position and tighten using an Allen key. The used wire end must be cut off before reconnection. The terminal screw must only be retightened once to prevent the litz wires from breaking. To prevent damage to the contact, the wire/cable must be mechanically held at an appropriate distance from the connection point (e.g., when used in a plate cut out). For notes on correct execution, see DIN VDE 0100-520:2003-06. Unused connections must be tightened with maximum torque.
Cineál D7
Tástálacha DIN VDE 0627/86
Leithead 21 mm
Airde 34.8 mm
Fad 21 mm
Sraith HC-HS
Ginearálta for HC-D7 housing, axial connection 2.0 mm, Allen key
Feidhmchlár Power
Cineál táirge Contact insert with a fixed no. of positions
Nóta tionóil To ensure correct use, installation in housing with IP54 protection or better is required
Sruth rátáilte 40 A
Athbhreithniú airteagail 04
Trastomhas teagmhála 4 mm
Ábhar teagmhála Copper alloy
Soicéad heicseagánach SW2,0
Uimhriú teagmhála 1 - 2
Chasmhóiminte teannaithe 0.5 Nm ... 0.8 Nm (Mounting screws for mounting in the HEAVYCON housing)
Próifíl nasc 2+PE
Céim an truaillithe 3
Líníocht thoisí
Líon na bpost 2
Voltas borrtha rátáilte 6 kV
Catagóir róvoltais III
Teicneolaíocht nasctha Axial screw connection
Cineál ábhar teagmhála turned
Líon na dteagmhálacha cumhachta 2
Voltas rátáilte (III/3) 400 V
Trasghearradh seoltóra 4 mm² ... 10 mm² (The cross section specification refers to the geometric cross section of the cable used)
Ábhar iompróra teagmhála PC
Ábhar dromchla teagmhála Ag
Timthriallta iontrála/aistarraingthe ≥ 500
Trasghearradh nasc AWG 10 ... 8
Teocht chomhthimpeallach (oibriú) -40 °C ... 125 °C (including heating up of contacts)
Ceangal de réir an chaighdeáin IEC / EN
Rialacháin thógála agus tástála DIN VDE 0627/86
Rátáil inadhainteachta de réir UL 94 V0
Fad stialladh na sreinge aonair 8 mm +1 mm

Cur Síos ar an Táirge

Contact insert, number of poles: 2+PE, size: D7, power contacts: 2, Female, Axial screw connection, 400 V, 40 A, 4 mm² ... 10 mm², Application: Power
Príomhghnéithe
  • Cáilíocht ghrád tionsclaíoch
  • Comhlíontach le RoHS
  • Deimhnithe CE
  • Barántas 1 bhliain

Doiciméid Táirge

Bileog Sonraí

Sonraíochtaí teicniúla agus sonraí feidhmíochta

Lámhleabhar Úsáideora

Treoir suiteála agus oibríochta

Top