| Paraiméadar | Luach |
|---|---|
| PoDL Power Class 11 | |
| MTTF | 185.12 Years (SN 29500 standard, temperature 25 °C, duty cycle 21%) |
| Doimhneacht | 119 mm |
| Leithead | 45 mm |
| Airde | 130 mm |
| Ginearálta | Telephone and on-site support (for a fee) |
| Bainistíocht | Web-based management (HTTP/HTTPS) |
| Iomarcaíocht | MRP (Media Redundancy Protocol) |
| Soilse LED comhartha | Data Receiving, Link Status |
| Tógáil | Sample book |
| Cineál Táirge | Switch |
| Moill Comhartha | ≥ 1.9 μs (Store-and-Forward mode, 10/100/1000 MBit/s, depending on frame size) |
| Voltas tástála | 500 V DC |
| Slándáil Calafoirt | MAC-based, RADIUS (IEEE 802.1X), MAC Authentication Bypass |
| Teaghlach Táirgí | Managed Switch 2000 |
| Ábhar sliogáin | Fiber-reinforced polycarbonate |
| Voltas soláthair | 20 V DC ... 32 V DC |
| Cineál nasc | RJ45 |
| Diagnóis áitiúil | US1/2 Supply Voltage US1, US2 Green LED |
| Feidhmeanna Eile | MMS & GOOSE Transmission (IEC 61850-8-1) |
| Tonnán iarmharach | 3.6 VPP(within the permissible voltage range) |
| Scéim Toise | |
| Feidhmeanna Scagaire | Quality of Service (8 priority classes) |
| Nasc cumhachta | via COMBICON, max. conductor cross-section 1.5 mm² |
| Innéacs Cosanta | IP20 |
| Gnéithe Speisialta | Extended temperature range, Single Pair Ethernet ports with PoDL |
| Cineál gléasta | Rail mounting |
| Tábla Seoltaí MAC | 8k |
| Tomhaltas Cumhachta | 65 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
| Táscaire Stádais | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Cosán fíoraithe | 1 minute at FE 500 V DC |
| Cineál cosanta | III (VDE 0106) |
| Líon na gcainéal | 3 (RJ45 ports) |
| Luas tarchuir | 10/100/1000 MBit/s |
| Feidhmiúlacht Bhunúsach | Switch Store and Forward, IEEE 802.3 compliant |
| Céim an truaillithe | 2 |
| Paraiméadú IP | DHCP-Client |
| Voltas soláthair (DC) | 24 V DC (Simultaneous PoDL power supply according to IEEE 802.3cg) |
| Fad Tarchuir | 100 m (per segment) |
| Meán Tarchuir | copper |
| Creathadh (seirbhís) | according to IEC 60068-2-6: 5g, 150 Hz |
| Tuairteanna (i seirbhís) | 30g (EN 60068-2-27) |
| Feidhmeanna diagnóiseacha | RMON History |
| Sioncrónú Ama | SNTP (Simple Network Time Protocol) |
| Fisic Tarchuir | copper |
| Rannóg Seoltóra AWG | 24 ... 16 |
| Astaíocht cur isteach | EN 61000-6-4 |
| Brú Aeir (Seirbhís) | 80 kPa ... 110 kPa up to 2000 m above sea level (No derating) |
| Friotaíocht cur isteach | EN 61000-6-2 |
| Roinn seoltóra righin | 0.25 mm² ... 1.5 mm² |
| Fad le dí-insliú | 9 mm |
| Rang comhréireachta PROFINET | Conformance-Class B |
| Roinn seoltóra solúbtha | 0.25 mm² ... 1.5 mm² |
| Uasmhéid Ionsú Reatha | 2.2 A (Us= Min, TAMB= Max, SPE = 8x max. PoDL Power, 100% data traffic on all connected ports) |
| Ionsú Reatha Tipiciúil | 1.03 A (to Us= Nom, TAMB= 25°C, SPE = 4x max. PoDL Power, 100% data traffic on all connected ports) |
| Teocht Chomhthimpeallach (Seirbhís) | -40 °C ... 70 °C |
| Comhoiriúnacht leictreamaighnéadach | Compliance with EMC Directive 2014/30/EU |
| Comhlíonadh treoracha EMC | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Nóta faoin gcineál nasc | Autonegoation and Autocrossing |
| Feidhm an mhodúil PROFINET | PROFINET Device |
| Brú Aeir (Stóráil/Iompar) | 79 kPa ... 108 kPa up to 2000 m above sea level (No derating) |
| Stádas agus Tásca Diagnóiseacha | LEDs: US1, US2 (Power Supply), Fail (Alarm Contact), 2 LEDs for each Ethernet port (Link/Activity and Speed) |
| Taise aeir incheadaithe (seirbhís) | 10 % ... 95% (non-condensing) |
| Teocht Chomhthimpeallach (Stóráil/Iompar) | -40 °C ... 85 °C |
| Taise aeir incheadaithe (stóráil/iompar) | 10 % ... 95% (non-condensing) |
| Saor ó shubstaintí fliucha vearnais suaiteacha | Yes |
| Uasmhéid Chumhachta Scaipthe le Coinníoll Ainmniúil | 12 W (Vin= max, tAMB= Max, IPSE= 8x IPoDLmax, 100% data traffic on all connected ports) |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta