| Paraiméadar | Luach |
|---|---|
| 18 V DC ... 30 V DC | |
| Fiús | electronic |
| Nóta | Interference emission |
| Cineál | Male |
| Dath | gray (RAL 7042) |
| Doimhneacht | 52 mm |
| Leithead | 12.3 mm |
| Airde | 45 mm |
| Ginearálta | When mounted in rows without convection cooling, the nominal device current should only be led to a maximum of 80% due to the thermal effect during continuous operation (100% operating factor).Special precautionary measures must be taken in systems or machines, to prevent components from restarting (e.g., use of a safety PLC).Parallel connection of multiple circuit breakers is not permitted. |
| Cineál táirge | Device circuit breakers |
| Titim voltais | 100 mV (at IN) |
| Tástáil taise | 96 h, 95 % RH, 40 °C |
| Cineál gléasta | on base element |
| Am múchta | 200 ms (see time/current characteristic curve) |
| Aitheantas | UL Listed UL 508 |
| Teaghlach táirgí | CB E |
| Líon na gcainéal | 1 |
| Moill lasctha | typ. 2 ms |
| Modh tripping | E (electronic) |
| Athbhreithniú airteagail | 03 |
| Céim truaillithe | 2 |
| Modh ceangail | pluggable |
| Eilimint sábháilteachta teipe | 6 A DC |
| Voltas oibriúcháin | 24 V DC |
| Diomailt cumhachta | 0.81 W (Nominal operation) |
| Sruth ainmniúil IN | 4 A |
| Neart tréleictreach | max. 30 V DC (Load circuit) |
| Líníocht thoisí | |
| Líon na bpost | 1 |
| Voltas borrtha rátáilte | 0.5 kV |
| Céim chosanta | IP30 (Actuation area) |
| Ualach toilleasach uasta | 20000 µF |
| Fiús cúltaca riachtanach | not required, integrated failsafe element |
| Ainmniú caighdeánach | EMV |
| Dí-rátáil teochta | 4 A (at 50 °C) |
| Doimhneacht iomlán an mhodúil | 77.3 mm |
| Leithead iomlán an mhodúil | 12.3 mm |
| Creathadh (oibriú) | 3g (according to IEC 60068-2-6, Test Fc) |
| Airde iomlán an mhodúil | 90 mm |
| Cineál nasc teagmhála | floating signal contact |
| Múchadh faoi-voltais | < 14 V (typ. OFF) |
| Caighdeáin/sonraíochtaí | EN 61000-6-3 |
| Teorannú reatha gníomhach | typ. 1.25 x IN |
| Sruth ciorcaid dúnta I0 | typ. 8 mA (When switched on) |
| MTBF (IEC 61709, SN 29500) | 8320000 h (at 25 °C with 80 % load) |
| Uasmhéid reatha oibriúcháin Imax | 0.5 A |
| Íosmhéid reatha oibriúcháin Imin | 10 mA |
| Teocht chomhthimpeallach (oibriú) | -25 °C ... 50 °C (non-condensing) |
| Uasvoltas oibriúcháin UmaxDC | 30 V DC |
| Íosvoltas oibriúcháin UminDC | 10 V DC |
| Rátáil inadhainteachta de réir UL 94 | V-0 |
| Teocht chomhthimpeallach (stóráil/iompar) | -40 °C ... 70 °C |
Sonraíochtaí teicniúla agus sonraí feidhmíochta
Treoir suiteála agus oibríochta